How to air-seal the floor of a house on pilings in a hot, humid climate

For a Charleston, South Carolina, house raised on wood pilings, BOWA's Doug Horgan recommends a continuous layer of XPS or foil-faced polyiso under the floor trusses to keep humid outdoor air from condensing beneath the air-conditioned subfloor, he writes in Fine Homebuilding.

The question came from a builder on the GBA forum planning a house in Climate Zone 3A, with the space between the pilings open to the weather behind louvered panels. If the dew point outside climbs above the indoor temperature of the cooled house, vapor pushes inward and can build up in the floor materials, writes Horgan, vice president of best practices at the remodeling firm BOWA. Over time that can rot framing, grow mold and ruin flooring.

He lists three fixes. Spray foam applied right under the subfloor keeps its outer face warm enough that water won't condense there and also blocks vapor, at a fair price when no ductwork runs in the floor. Horgan avoids foaming an entire floor, though, citing the risks of installation and the chemicals involved. A second route is to make the floor cavity part of the conditioned space. That means sealing around posts, beams, hardware, plumbing and wiring, and adding HVAC to it, from a single supply register with a return path to ducts run down the walls.

His preferred fix is an airtight, vapor-retarding layer of rigid foam across the bottom of the trusses: XPS or foil-faced polyiso, not EPS, which he says is too open to vapor. For thickness he points to IRC Table R806.5, written for unvented roof assemblies, which calls for 1/2 inch of rigid insulation in zone 3A. Running the table's footnote calculation for a 12- to 16-inch truss cavity filled with blown cellulose or fiberglass points to about 1 1/2 inches as the safer choice. The foam is covered with fiberglass-faced gypsum sheathing or plywood, and the rim and perimeter are sealed with spray foam.

Why it matters: Builders raising homes on the Southeast coast can size the foam under the floor from the unvented roof table. The hard part of the detail is the air seal at the rim and around the posts, beams and hardware that carry the house.

Sources

More in jobsite hacks